交流電流
真有效值電流*1
量程 | 分辨力 | 準確度*2 |
0.30 – 39.99A (40A刻度) | 0.01A | ± (3% + 20) ± (4% + 30) ± (4% + 30) ± (8% + 30) | 45Hz – 65Hz 30Hz – 45Hz *3 65Hz – 1KHz 20Hz – 30Hz *4 |
0.3 – 399.9A (400A刻度) | 0.1A | ± (3% + 2) ± (4% + 3) ± (4% + 3) ± (8% + 3) | 45Hz – 65Hz 30Hz – 45Hz *3 65Hz – 1KHz 20Hz – 30Hz *4 |
400 – 700A (400A刻度) | 1A | ± 5% ± 7% ± 7% 無特定值 | 45Hz – 65Hz 30Hz – 45Hz *3 65Hz – 1KHz 20Hz – 30Hz *4 |
*1. 正弦波,導體中心測量,開機自檢有相應指示圖標和電量指示(大于40小時計)
*2. RMS Min/Max: 加上10 counts
*3. ≥1A, 30Hz – 45Hz
*4. 均值模式, ≥2.5A, RMS Min/Max: 加上2%讀數
瞬時電流(振幅模式)**1
量程 | 分辨力 | 準確度 |
0.40 – 39.99A (40A刻度) | 0.2A | ± (3% + 30) ± (4% + 30) ± (4% + 30) ± (4% + 40) | 45Hz – 65Hz 30Hz – 45Hz **2 65Hz – 1KHz 20Hz – 30Hz **3 |
0.40 – 399.9A (400A刻度) | 2A | ± (3% + 3) ± (4% + 3) ± (4% + 3) ± (4% + 4) | 45Hz – 65Hz 30Hz – 45Hz **2 65Hz – 1KHz 20Hz – 30Hz **3 |
400 – 599A (400A刻度) | 4A | ± 3% ± 4% ± 4% ± 4% | 45Hz – 65Hz 30Hz – 45Hz **2 65Hz – 1KHz 20Hz – 30Hz **3 |
600 – 999A (400A刻度) | 4A | ± 7% ± 7% ± 7% ± 7% | 45Hz – 65Hz 30Hz – 45Hz **2 65Hz – 1KHz 20Hz – 30Hz **3 |
**1. 參考*1 **2. 參考*3 **3. ≥2.5A
頻率***1
量程 | 分辨力 | 準確度 |
0.5 – 999.9Hz | 0.1Hz | ±(0.2% + 3) |
1000 – 9999Hz | 1Hz | ±(0.2% + 3) |
***1. 參考*1
電流自動量程:觸發水平,5 Hz到1500 Hz,>0.7A RMS,1/2峰值電流
電流手動量程:觸發閾值,10 Hz到1000Hz,
40A量程 – ≥6A RMS / 400A范圍 – ≥40A RMS
直流電流
量程 | 分辨力 | 準確度 |
0.30 – 39.99A | 0.01A | ±(2% + 30) |
0.3 – 399.9A | 0.1A | ±(2% + 10) |
400 – 700A | 1A |
交流電壓(真有效值)/直流電壓
量程 | 分辨力 | 準確度 |
交流電壓 | 直流電壓 |
45Hz – 65Hz | 45Hz – 1KHz |
0 – 39.99V | 0.01V | ±(1.0% + 3) | ±(2.5% + 5) | ±(1.0% + 3) |
0 – 399.9V | 0.1V |
0 – 750V | 1V | ±(1.5% + 5) | ±(1.5% + 5) |
交流電壓,共模抑制比:> 80dB,直流到60Hz
直流電壓,常模抑制比:>11dB在50Hz或60Hz
共模抑制比:>84dB直流,50Hz或60Hz
電阻
量程 | 分辨力 | 準確度 |
0 – 399.9Ω | 0.1Ω | ±(1.0% + 10) |
0 – 3.999KΩ | 1Ω | ±(1.0% + 3) |
通斷